Soft Starter Contactor Vacuum Contactor Ckg Series for AC Motor

    • Model NO.: CKG
    • Number of Pole: 3
    • Type: Vacuum Contactor
    • Protective Characteristics: Vacuum Contactor
    • Theory: Vacuum Contactor
    • Usage: Vacuum Contactor
    • Specification: CE ISO9001 CCC
    • Electricity Type: Vacuum
    • Phase: 3
    • Circuit Breaker: Vacuum Contactor
    • Load: Vacuum Contactor
    • Size: Vacuum Contactor
    • Trademark: M&a
    • Origin: Wenzhou China


    Soft starter contactor vacuum contactor CKG series for AC motor
    1.Detail description 
    This series of vacuum contactors are suitable for the electricity network system 12kv below power network systems for installation of mechanical interlocking shaft between the two vacuum contactor can achieve mechanical interlock and interlock function, can also achieve electrical lockout.
    Mainly used to enhance the electronic control circuit as the pros and cons of conversion, dynamic braking, the main line switch, frequent operation, have the advantage of long mechanical life, high reliability, low maintenance, excellent breaking performance. This series of vacuum contactor also can be used to control the high pressure air the pros and cons of conversion to a load and as a master switch.

     
     2.Main Tech-Parameter
    CKG4 12KV Series AC vacuum contactor
    ModelTech parameter 160/12KV 250/12KV 400/12KV 630/12KV 800/12KV
    Main circuit rated voltage (KV) 12 12 12 12 12
    Main circuit rated current (A) 160 250 400 630 800
    Main circuit making capacity
    (A/100times)
    1600 2500 4000 6300 8000
    Main circuit break-make
    ability (A/25times)
    1280 2000 3200 5000 6000
    Maximum break ability (A/3times) 3200 3200 4500 6300 8000
    Mechanical life (times) 100 0000 100 0000 100 0000 100 0000 100 0000
    Electricity life AC3 (times) 25 0000 25 0000 25 0000 25 0000 25 0000
    Engineering lock life (times) 10 0000 10 0000 10 0000 10 0000 10 0000
    Power-frequency withstand voltage
    for main circuit(fracture)(kv)
    42 42 42 42 42
    Phase-phase phase -to current withstand voltage(KV) 42 42 42 42 42
    Lightning impulse withstand voltage (KV) 75 75 75 75 75
    Rated operate frequency (times/h) 300 300 300 300 300
    Engineering lock operate frequency (times/h) 30 30 30 30 30
    Terminal pressure(N) >100 >100 >100 >100 >100
    Clearance betweenopen contacts (mm) 6±0.5 6±0.5 6±0.5 6±0.5 6±0.5
    Over travel (mm) 1.5±0.5 1.5±0.5 1.5±0.5 1.5±0.5 1.5±0.5
    Weight(Kg) 30 30 30 30 30
    Main circuit resistance( Î¼Ω ) ≤200 ≤200 ≤200 ≤200 ≤200
    Secondary control voltage (v)
    AC&DC:110 220 380or can be customized
     
     
     
     

    Vehicle GPS Tracker

    GPS Personal Tracker Co., Ltd. , http://www.szgpstracker.com

    Previous Post: Dual Driver Supply C B Level Automatic Transfer Switch
    Next Post: Chinese and American scientists have developed silicon-based optical waveguides
    Home
    Recent Posts
    • Manufacturer 42 Inch LCD Display Full HD 3G WiFi…
    • Galvanized and Painted Perforated Steel Cable Tr…
    • Complete Set Cash Register POS
    • Rural lighting market in the eyes of a Taiwanese…
    • TI Unveils Breakthrough DLP HDTV Innovations Wit…
    • High-brightness and high-energy lamps are strict…
    • Zhang Yutao: Low-key work for high-profile peopl…
    • The era of 1TB SSD is coming: Intel Micron sends…
    • Novelty balloon series lamps increase design int…
    • Cheaper than 11 inch Air
    • 36.4 inch EIZO astronomical monitor released
    • U.S. Semiconductor Newcomers Transmit Apple to P…
    • China's LED lamp prices fell the most in Nov…
    • Hu Zhaoguang: Solving the "pseudo electrici…
    • Go to Hong Kong to buy electronic products or wi…
    • Enhanced Logic IC Layout Acquired by Japanese Fa…
    • Overseas giants hit China's panel industry f…
    • Breakthrough silicon crystal limit! IBM carbon n…
    • Analysis of Development Situation of Electrical …
    • The push behind smart meter development