Domestic lighting standard value reference

    1. Residential buildings
    Residential building lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    Ra

    living room

    General activity

    0.75m horizontal plane

    100

    80

    Writing, reading

    300

    bedroom

    General activity

    0.75m horizontal plane

    75

    80

    Bedside, reading

    150

    restaurant

    0.75m dining table

    150

    80

    kitchen

    General activity

    0.75m horizontal plane

    100

    80

    Console

    mesa

    150

    bathroom

    0.75m horizontal plane

    100

    80

    Note: Mixed lighting should be used



    2. Public buildings

    Commercial building lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    UGR

    Ra

    General store business hall

    0.75m horizontal plane

    300

    twenty two

    80

    High-end store business hall

    0.75m horizontal plane

    500

    twenty two

    80

    General supermarket business hall

    0.75m horizontal plane

    300

    twenty two

    80

    High-end supermarket business hall

    0.75m horizontal plane

    500

    twenty two

    80

    Cash register

    0.75m horizontal plane

    500

    -

    80


    Library building lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    UGR

    Ra

    General reading room

    0.75m horizontal plane

    300

    19

    80

    Reading rooms of countries, provinces and cities and other important libraries

    0.75m horizontal plane

    500

    19

    80

    Old age reading room

    0.75m dining table

    500

    19

    80

    Zhenshan and the reading room

    0.75m horizontal plane

    500

    19

    80

    Showroom, catalogue hall (cash hall)

    0.75m horizontal plane

    300

    19

    80

    Library

    0.75m horizontal plane

    50

    -

    80

    Workshop

    0.75m horizontal plane

    300

    19

    80

    Office building lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    UGR

    Ra

    Ordinary office

    0.75m horizontal plane

    300

    19

    80

    High-end office

    0.75m horizontal plane

    500

    19

    80

    meeting room

    Actual working surface

    300

    19

    80

    Reception room, reception

    0.75m horizontal plane

    500

    -

    80

    business Hall

    0.75m horizontal plane

    300

    twenty two

    80

    design room

    0.75m horizontal plane

    500

    19

    80

    Document sorting, copying, distribution room

    0.75m horizontal plane

    300

    -

    80

    Data archive

    0.75m horizontal plane

    200

    -

    80

    Hotel building lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    UGR

    Ra

    customer

    room

    General activity area

    0.75m horizontal plane

    75

    -

    80

    bedside

    0.75m horizontal plane

    150

    -

    80

    desk

    mesa

    300

    -

    80

    bathroom

    0.75m horizontal plane

    150

    -

    80

    Chinese restaurant

    0.75m horizontal plane

    200

    twenty two

    80

    Western restaurant, bar room, cafe

    0.75m horizontal plane

    100

    -

    80

    Multifunction

    ground

    300

    twenty two

    80

    Foyer, general service desk

    ground

    300

    -

    80

    Lounge

    ground

    200

    twenty two

    80

    Room floor corridor

    ground

    50

    -

    80

    kitchen

    mesa

    200

    -

    80

    laundry room

    0.75m horizontal plane

    200

    -

    80

    School building lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    UGR

    Ra

    classroom

    Class desktop

    300

    19

    80

    laboratory

    Experimental desktop

    300

    19

    80

    Art classroom

    desktop

    300

    19

    80

    Multimedia Classroom

    0.75m horizontal plane

    300

    19

    80

    Classroom blackboard

    Blackboard

    300

    80

    Hospital building lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    UGR

    Ra

    Treatment room

    0.75m horizontal plane

    300

    19

    80

    Laboratory

    0.75m horizontal plane

    500

    19

    80

    Operating room

    0.75m horizontal plane

    750

    19

    80

    Clinic

    0.75m horizontal plane

    300

    19

    80

    Waiting room, registration hall

    0.75m horizontal plane

    200

    19

    80

    Ward

    ground

    100

    twenty two

    80

    Nurse station

    0.75m horizontal plane

    300

    -

    80

    pharmacy

    0.75m horizontal plane

    500

    19

    80

    Intensive care unit

    0.75m horizontal plane

    300

    19

    80

    Exhibition hall lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    UGR

    Ra

    General exhibition hall

    ground

    200

    twenty two

    80

    High-end exhibition hall

    ground

    300

    twenty two

    80

    Note: Ra in the exhibition hall above 6m can be reduced to 60.


    Sports building lighting quality standard value

    category

    GR

    Ra

    No color TV broadcast

    50

    50

    Color TV broadcast

    50

    80

    Note: The GR value is only available for outdoor sports venues.

    3. Industrial construction

    Industrial building general lighting standard value

    Room and place

    Reference plane and its height

    Illumination standard value
    (Lx)

    UGR

    Ra

    Remarks

    Universal room or place

    laboratory

    general

    0.75m horizontal plane

    300

    twenty two

    80

    Additional local illumination

    fine

    0.75m horizontal plane

    500

    19

    80

    Additional local illumination

    test

    general

    0.75m horizontal plane

    300

    twenty two

    80

    Additional local illumination

    Fine, color requirements

    0.75m horizontal plane

    750

    19

    80

    Additional local illumination

    Measuring room

    0.75m horizontal plane

    500

    19

    80

    Additional local illumination

    Substation

    Power distribution unit

    0.75m horizontal plane

    200

    -

    60

    Transformer room

    ground

    100

    -

    20


    4 , public places

    Public place lighting standard value

    Room or place

    Reference plane and its height

    Illumination standard value (Lx)

    UGR

    Ra

    hall

    ordinary

    ground

    100

    -

    60

    High grade

    ground

    200

    -

    80

    corridor,
    Flow area

    ordinary

    ground

    50

    -

    60

    High grade

    ground

    100

    -

    80

    Stairs, platforms

    ordinary

    ground

    30

    -

    60

    High grade

    ground

    75

    -

    80

    escalator

    ground

    150

    -

    60

    Toilet, bathroom

    ground

    ground

    75

    60

    High grade

    ground

    150

    80

    Elevator lobby

    ordinary

    ground

    75

    60

    High grade

    ground

    150

    80

    lounge

    ground

    100

    twenty two

    80

    Storage room, warehouse

    ground

    100

    60

    garage

    Parking room

    ground

    75

    28

    60

    Repair room

    ground

    200

    25

    60

    Note: The lighting standard values ​​of power stations and substations in residential and public buildings are selected according to the table.


    Webpage editing: Lulangjia, China Lighting Network

    FILE SAFE

    Tisineo (Hi-Tech) Technology Co. Ltd , http://www.tisineosafe.com

    Previous Post: Key Points of Work of China Lighting Association in 2007
    Next Post: China's lighting market will add another pearl
    Home
    Recent Posts
    • China OEM Brushed Aluminium Tube
    • Inspiration from Bingo Bingo B615 Wireless Headp…
    • 350W Glass Jar Electric Juice Blender (KD-316)
    • High Quality Tube 5X20mm Fuse Holder
    • 17amirp Thermal Protector with 4 to 10 Seconds T…
    • High Quality Forklift Parts Forklift Fuse 350A
    • Electrical Motor for Home Appliance/Air Conditio…
    • video Processor Surge Protection Device
    • Line non-metaphysical system
    • 700-2700MHz 800-2500MHz Patch Panel Wall Mounted…
    • Mobile Phone Accessories Shockproof Phone Cover …
    • Yogurt Ice Cream Machine (HM716) Hot sale produc…
    • Disconnector Switch Disconnect Switch Isolator S…
    • Ceramic Gbc Car Fuse Ceramic Auto Fuse Ceramic E…
    • SMF-3 400A Overhead Fuse Carrier
    • Car Panel Mounted Blade Fuse Holder (QS02)
    • Hag II Series Plastic Distribution Box
    • Three questions "Solar Building City"
    • 1600W Wall Mounted ABS Plastic Hair Dryer for Ho…
    • Australia's Tenrod has released a new silico…