    XLPE Armoured Power Cable1 Information:

    A. Number of Cores:
    1, 2, 3, 3+1, 3+2, 3+3, 4, 4+1, 4+2, 5

    B. Construction:
    Stranded copper conductor for single and shaped conductors for multi-core cables, XLPE insulated, PVC bedding, zinc plating steel wire armored and PVC sheathed cables.

    C. Nominal Section
    Area(mm2): 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

    2 Standard:
    IEC60502, BS6346, AS/NZS, UL, or as customer's request.

    3 The Rated Voltage(kv):
    0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
    4 Application:
    These cables are most suitable for direct burial or for installation on trays or ducts, where there is a risk of mechanical damage, armoured cables should be used. The products can be produced according to our factory specification which is equivalent to the standard IEC60502.

    5 Operating Characteristics:
    Max. Permission conductor continous operating temperature of conductor 90 ° C
    Max. Short-circuit temperature of conductor shall not exceed 250 ° C (5s maximum duration)
    The ambient temperature under installation of cable should not below 0 ° C
    The bending radius of a single-core cable should not less than 20 times of outer diameter of the cable

    6 Instruction
    I. Executive Standard: GB12706.1.3 adopts international electrician committee IEC60502
    II. Working Features:
    1. Environment temperature should be no lower than 0 for laying, the cable fall without limitation
    2. The min bending radius of cable is stipulated as follows: Single core: 20(d+D) 5% three cores: 15(d+D) 5% (D is actual diameter of cable; D is actual outer diameter of conductor).
    3. Operation temperature of cable PVC sheath is no more than 90.
    4. Max rated temperature of cable conductor is 90, and no higher than 250 in time of short circuit (max. Lasting time is no longer than 5s). XLPE Armoured Power Cable1 Information:

    A. Number of Cores:
    1, 2, 3, 3+1, 3+2, 3+3, 4, 4+1, 4+2, 5

    B. Construction:
    Stranded copper conductor for single and shaped conductors for multi-core cables, XLPE insulated, PVC bedding, zinc plating steel wire armored and PVC sheathed cables.

    C. Nominal Section
    Area(mm2): 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

    2 Standard:
    IEC60502, BS6346, AS/NZS, UL, or as customer's request.

    3 The Rated Voltage(kv):
    0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
    4 Application:
    These cables are most suitable for direct burial or for installation on trays or ducts, where there is a risk of mechanical damage, armoured cables should be used. The products can be produced according to our factory specification which is equivalent to the standard IEC60502.

    5 Operating Characteristics:
    Max. Permission conductor continous operating temperature of conductor 90 ° C
    Max. Short-circuit temperature of conductor shall not exceed 250 ° C (5s maximum duration)
    The ambient temperature under installation of cable should not below 0 ° C
    The bending radius of a single-core cable should not less than 20 times of outer diameter of the cable

    6 Instruction
    I. Executive Standard: GB12706.1.3 adopts international electrician committee IEC60502
    II. Working Features:
    1. Environment temperature should be no lower than 0 for laying, the cable fall without limitation
    2. The min bending radius of cable is stipulated as follows: Single core: 20(d+D) 5% three cores: 15(d+D) 5% (D is actual diameter of cable; D is actual outer diameter of conductor).
    3. Operation temperature of cable PVC sheath is no more than 90.
    4. Max rated temperature of cable conductor is 90, and no higher than 250 in time of short circuit (max. Lasting time is no longer than 5s).

    SAA Adapter

    SAA Adapter,Audio Adapter ,Power Adapter ,Network Adapter

    Power Adaptor Co., Ltd. , http://www.nbadapter.com

    Previous Post: Nyy Cable Flexible Cable 3 Cores Flexible Electrical Copper Wire
    Next Post: Networking U/UTP Cat. 6A PVC Communication Patch Cables
    Home
    Recent Posts
    • Surfaced Mounted 400X400 500X500 600X600 620X620…
    • HDMI to VGA Conversion Cable
    • 40W Ra90 Ugr19 600X600mm LED Panel Light for Com…
    • Promotion 4u Energy Saving Fluorescent Lamp
    • ETL Listed FTP Cat5e Cat5e LAN Cable
    • Blue LED Work Light Forklift Warning Spotlight f…
    • Car LED Headlight Bulbs 50W 8000lm CREE Chips Cs…
    • 3W SMD2835 LED Spotlight GU10 LED with Ce RoHS
    • Network Cable UTP Cat 5e Cable Patch Cord Blue C…
    • FTTH Optical Fiber Cable Terminal Tool Kit
    • Multi-Functional Automatic Flow Control Valve fo…
    • Hot Galvanized Steel Monopole Tower
    • 13 LED Flashlight/ Torch with Bottle Opener (ET-…
    • Snap Action 6 Pins Double Pole Double Throw Micr…
    • 1600W LED 20m High Mast Light with Galvanized Po…
    • 14m Tapered Painted Steel Poles
    • 8X10W RGBW LED Moving Head Beam LED Spider Light
    • 35kv Single Circult Overhead Transmission Steel …
    • OEM Available Tapered Corrosion Resistant Hot-DI…
    • 100W/150W/200W/300W High Mast LED Parking Lot Li…