AC Surge Protective Device SPD, Surge Arrester

    Model NO.: SUP1
    Shape: Cuboid
    Material: Ceramic
    Certification: ROHS, ISO9001, CCC, CE
    Brand: Suntree/OEM
    DC: 1000V 500V
    AC: 275V 320V 385V 420V
    Ka: 5ka-100ka
    Certificate: CE
    Protection Class: IP40
    Operating Temperature: 5°c - +50°c
    Poles: 1p 2p 3p 4p
    Max Working Volt: 250V AC/30V DC
    Hard Wire: 4-25
    Flexible Wire: 4-16
    Trademark: SUNTREE/oem
    Specification: CE
    Origin: Zhejiang China
    HS Code: 853540000
    AC Surge Protective Device Spd,Surge Arrester

    Description:
    Intensity of Remote Signalling Alarm Contact
    Failure indication and centralized remote signalling alarm dry contacts;
    High discharge capacity and low residual voltage;
    Over-temperature protection;
    IP20, UL94 V0

    Model Number SUP1
    SPD according IEC 61643-1 Class II
    SPD according EN 61643-11 Type 2
    Operating Temperature Range -40ºC~+80ºC
    Relative Humidity ≤95%(25ºC)
    Atmospheric Pressure 86~106kPa
    Working Frequency 50/60Hz
    Rated Working Voltage Uo 230V/400V~
    Max Continuous Operating Voltage Uc(L-N) 275V/320V/385V/420V ~
    Mode of protection L-N/N-PE
    Nominal Discharge Current In(8/20μs)(L-N) 20kA
    Max Discharge Current Imax (8/20μs) (L-N) 40kA
    Voltage Protection Level Up(L-N) ≤1.2kV
    Max. mains-side Overcurrent Protection 80A(gL/gG)
    Cross sectional area for wiring terminal connected to conductor Stranded:4~25mm²
    Solid Wire: 4~35mm²
    Max. Cross-sectional Area For Remote Signaling Interface 1.5mm²
    Torque: wiring terminal/remote signaling interface 2.5Nm
    Enclosure material PBTV-0
    Degree of protection(IP code) IP20
    Mounting DIN35mm rails


    Solar DC SPD
    The SUP series Surge Protection are designed to protect against lightning surge voltages in photovoltaic power supply networks.

    These units must be installed in parallel on the DC networks to be protected and provide common and differential modes protection. The SUP series is available for the main operating voltages in photovoltaic: 1000 Vdc.

    The use of SUP series Surge Protection is recommended at both ends of the DC power supply line (solar panel side and inverter/converter side),

    Especially if the line routing is external and long. The electrical diagram of the SUN-S40 series is based on high energy PV equipped with specific thermal disconnectors and related failure indicators.

    The SUP series is made with plug-in modules to allow a fast and easy maintenance in case of failure (disconnection from the DC network).

    SUP2-PV series surge protector SUP4-PV
    PV DC specific (LEC 6614-1/EN 61643-11)
    Pole 2 pole 3 pole
    Electrical Parameter
    Classifical test II II
    Uoc max (V DC) 500 900
    Uc (V DC) 500 1000
    In(8/20)us (KA) 20 20
    Imax(8/20)us (KA) 40 40
    Up (KV) 2.0 3.8
    Remote control and indication
    Indication window
    Plug-in module
    Remote signal contact
    Remote signal contact Max working volt 250V AC/30V DC 250V AC/30V DC
    Max working amp 1A (250V/AC) 1A (250V/AC) 1A (250V/AC)
    1A (30V DC) 1A (30V DC) 1A (30V DC)
    Wiring & installation
    Wiring capacity(mm2) Hard wire 4-25 4-25

     
    Flexible wire 4-16 4-16
    Stripping length 10 10
    Terminal screwa M5 M5
    Torque(Nm) Main ciruit 3.5 3.5
    Remote signal contact 0.25 0.25
    Protection class All profile IP40 IP40
    Connection port IP20 IP20
    Installation environment No obvious shock and vibration
    Altitude(m) ≤ 2000 ≤ 2000
    Working temperature -3.0--+70 -3.0--+70
    Relative humidity 30%-90% 30%-90%
    How to install Install with H35-7.5/DIN35 stell mounting rail
    Size(mm) (W*H*L) W 36 54
    H 90 90
    L 67.6 67.6
    Weight (KG) 0.25 0.38

    Nominal PV system volt 600V 100V 1200V
    MCOV(UCPV) 700V DC 1170V DC 1200V DC
    Max system discharge Current (8/20us) (Imax) 40KA 40KA 30KA
    Volt protection leve (UP) ≤ 2.5KV ≤ 4.0KV ≤ 4.5KV
    Volt protection Level at 5KA (UP) ≤ 2.0KV ≤ 3.5KV ≤ 4.0KV
    Integrate fuse breaking capacity/interrupting rating 30KA/1000V DC 30KA/1000V DC 30KA/1200V DC
    Technology Short-circuit interruption (SCI) overcurrent protection
    Operating temperature range -40 to +80
    Nominal discharge current 12.5KA
    Response time (ta) <25ns
    Operating state/fault indication Green (good) / Red (replace)
    Mounting 35mm DIN Rail per EN 60715
    Degree protection IP20
    capacity 3 modules DIN 43880

    phone:008615067704943

    Emi Rfi Shielding Materials

    EMI shielding raw materials  is used for make EMI shielding products.  It also can use directly for EMI RFI shielding . Conductive fabrics is copper nickel fabric or pure copper fabric.

    It is used for making shielding gasket or shielding garments, conductive foam is for making X-Y-Z conductive gasket, Conductive Mesh is for shielding window. Silver fabric and Silver Fiber is for making good quality shielding garments.

    EMI shielding raw materials

    EMI shielding products

    shielding gasket

    EMI RFI Shielding Materials

    Emi Rfi Shielding Materials,Emi Shielding Fabric,Emi Shielding Mesh,Emi Shielding Honeycomb

    JINAN EMI SHIELDING TECHNOLOGY CO., LTD. , http://www.emirfi.com

    Previous Post: High Quality Cap Shape Fuse
    Next Post: China will study and propose energy consumption standards for electronic information products
    Home
    Recent Posts
    • Outdoor Garden LED Integrated Solar Street Light…
    • 3 Years Warranty UL LED Floodlight Marine Underw…
    • High Quality Cap Shape Fuse
    • AC Surge Protective Device SPD, Surge Arrester
    • China will study and propose energy consumption …
    • LED Panel Light with Daylight Sensor Function Li…
    • Garden Bug Zapper Solar Battery Mosquito Killer …
    • Weather Resistant Maritime Industrial Telephone …